Product Information

Analogue output 4 – 20 mA, 0 – 20 mA, 0 – 10 V or 0 – 5 V
D/A conversion 16 bit very low drift and very high accurate DAC
External resolution Analogue output changes up to 60 000 steps
A/D Conversion
Load cell signal range 19 mV to +19 mV
Minimum load cell signal range < 1 mV
Linearity < % 0.01
Temperature drift < 0.007 % FSR / ºC
A/D conversion 24 bit Delta-Sigma ratiometric with integrated analogue and digital filters
Internal resolution Up to 16 000 000 counts
Weighing
Calibration Performed with rotary switches on the front of instrument.
Electronic calibration eCal calibration in high accuracy without test weights.
Fast calibration Automatic zero adjustment and span adjustment with load 20% max.
Digital filter 3 step adjustable smart adaptive filter.
Set points 2 programmable free setpoints, Relay contact: 240 VAC, 0.25 A or 30 VDC 0,15 A.

Load Cells
Excitation 5 VDC
Number of load cells Up to 4 load cells 350 Ω or up to 12 load cells 1100 Ω (min. 85 Ω)
Connection 4 wire technique.
Setup & Communication
Front panel 3 x status LED, 2 x rotary switches.
RS-232C For programming from PC or PLC.
Set up and adjustment software xFace.
Power
Power supply 12 – 28 VDC, max. 0.2 A
Environment and Enclosure
Operation temperature Between -15°C and +55°C
Humidity At 85% RH max, non-condensing.
Enclosure Polyamide, for DIN-rail mount, IP20.
Dimensions Front width: 22,5 mm, front length: 99 mm, height: 114,5 mm

 