Description

Accuracy
Accuracy class OIML Class III
EU Type approval 10.000 division
Linearity % 0.0015 FS
Temperature coefficient ≤ 2 ppm/°C
Display and Keyboard
Display 6 digits, 7 segments, LED 13,5 mm high
Status annunciators Gross, net, motion, centre of zero, units
Keyboard 5-key (function, GN, tare/clear, zero, print)
Key lock Keys can be locked against unauthorized access
A/D Converter
Type 24 bit Delta-Sigma ratiometric ADC
Conversion rate Up to 1600 conversions per second
Minimum input sensitivity 0.4 μV/d (Approved); 0.1 μV/d (Non approved)
Analogue input range 0 mV to +18 mV (unipolar); – 18 mV to +18 mV (bipolar)
Resolution Internal up to 16.000.000; up to 10.000 increment (Approved); up to 999.999 increment (Non approved)
Scale Calibration and Functions
Calibration Standard: With etalon weights via keys or via IndFace1X software on serial port
eCal: Electronic calibration without etalon weights
Fieldbus: Fieldbus commands for zero and span adjustments
sCal: Span calibration of non-emptied tanks.
Digital filter 10 step adjustable adaptive digital filter
Weighing functions Tare, zeroing, auto zero tracking, motion detection, auto-zero at power-up.

Load Cell Connection
Excitation 5 VDC, max. 125 mA
Number of load cells Up to 8 load cells 350 Ω or up to 24 load cells 1100 Ω (min. 43 Ω)
Connection 4 or 6 wire technique. Cable length 1000 m/mm² for 6 wire connection
Other functions Label number, gross, tare indication
Digital Inputs / Outputs
Digital outputs 5 set points with relay contact output.
Digital inputs 4 inputs are programmable for zeroing, tare, clear, hold, peak, print etc.
Interfaces
Analogue Programmable to 4 – 20 mA, 0 – 20 mA, 0 – 5 VDC or 0 – 10 VDC
RS-232C 1200 to 115200 baud, programmable
Continuous, Printer, BSI (Baykon Serial Interface) protocol
RS-485 1200 to 115200 baud, 8 none 1, 7 even 1, 7 odd 1, 8 even 1 or 8 odd 1, Up to 31 units on the bus
Modbus RTU 1200 to 115200 baud, 8 none 1, 8 even 1 or 8 odd 1, up to 31 units on the RS-485 bus
Ethernet TCP/IP or Modbus TCP 10 Mbit/s (half duplex), galvanically isolated
EtherNet/IP 10 Mbit/s or 100 Mbit/s, full dublex, galvanically isolated
EtherCAT 100 Mbit/s, full dublex, galvanically isolated
Profibus Profibus DP V1. 9,6 kbit/s to 12 Mbit/s automatic baud rate detection
Profinet 100 Mbit/s (full duplex), galvanically isolated
CANopen 10 kbit/s to 1 Mbit/s automatic baud rate detection
CC-Link 156 Kbit/s – 10 Mbit/s (selectable), baud rate
POWERLINK 100Mbit/s, half duplex

Additional information

Weight 0.576 kg
Dimensions 18 × 11 × 6 cm

Product Information

Analogue output 4 – 20 mA, 0 – 20 mA, 0 – 10 V or 0 – 5 V
D/A conversion 16 bit very low drift and very high accurate DAC
External resolution Analogue output changes up to 60 000 steps
A/D Conversion
Load cell signal range 19 mV to +19 mV
Minimum load cell signal range < 1 mV
Linearity < % 0.01
Temperature drift < 0.007 % FSR / ºC
A/D conversion 24 bit Delta-Sigma ratiometric with integrated analogue and digital filters
Internal resolution Up to 16 000 000 counts
Weighing
Calibration Performed with rotary switches on the front of instrument.
Electronic calibration eCal calibration in high accuracy without test weights.
Fast calibration Automatic zero adjustment and span adjustment with load 20% max.
Digital filter 3 step adjustable smart adaptive filter.
Set points 2 programmable free setpoints, Relay contact: 240 VAC, 0.25 A or 30 VDC 0,15 A.

Load Cells
Excitation 5 VDC
Number of load cells Up to 4 load cells 350 Ω or up to 12 load cells 1100 Ω (min. 85 Ω)
Connection 4 wire technique.
Setup & Communication
Front panel 3 x status LED, 2 x rotary switches.
RS-232C For programming from PC or PLC.
Set up and adjustment software xFace.
Power
Power supply 12 – 28 VDC, max. 0.2 A
Environment and Enclosure
Operation temperature Between -15°C and +55°C
Humidity At 85% RH max, non-condensing.
Enclosure Polyamide, for DIN-rail mount, IP20.
Dimensions Front width: 22,5 mm, front length: 99 mm, height: 114,5 mm

 